DatasheetsPDF.com

Operational Amplifier. TL322I Datasheet

DatasheetsPDF.com

Operational Amplifier. TL322I Datasheet






TL322I Amplifier. Datasheet pdf. Equivalent




TL322I Amplifier. Datasheet pdf. Equivalent





Part

TL322I

Description

Dual Low-Power Operational Amplifier



Feature


ą TL322C, TL322I DUAL LOWĆPOWER OPER ATIONAL AMPLIFIERS ą SLOS086 − D25 67, OCTOBER 1979 − REVISED OCTOBER 19 90 • Wide Range of Supply Voltages S ingle Supply . . . 5 V to 30 V Dual Sup plies . . . ± 2.5 V to ± 15 V • Cla ss AB Output Stage • True Differentia l Input Stage • Low Input Bias Curren t • Internal Frequency Compensation Short-Circuit Protection D OR P PAC.
Manufacture

Texas Instruments

Datasheet
Download TL322I Datasheet


Texas Instruments TL322I

TL322I; KAGE (TOP VIEW) 1OUT 1 1IN − 2 1IN + 3 VCC− /GND 4 8 VCC + 7 2OUT 6 2IN 5 2IN + symbol (each amplifier) de scription The TL322C and the TL322I are dual operational amplifiers similar in performance to the uA741 but with seve ral distinct advantages. They are desig ned to operate from a single supply ove r a range of voltages from 5 V to 30 V. Operation from split su.


Texas Instruments TL322I

pplies is also possible provided the dif ference between the two supplies is 5 V to 30 V. The common-mode input range i ncludes the negative supply. Output ran ge is from the negative supply to VCC 1.5 V. Quiescent supply currents per amplifier are typically less than one-h alf those of the uA741. The TL322C is c haracterized for operation from 0°C to 70°C. The TL322I is .


Texas Instruments TL322I

characterized for operation from −40° C to 85°C. IN + + IN − − Outp ut TA 0°C to 70°c AVAILABLE OPTIONS VIO MAX AT 25°C PACKAGE SMALL OUTL INE (D) PLASTIC DIP (P) 10 mV TL322C D TL322CP 0°C to 70°c 8 mV TL322I D TL322IP D packages are available ta ped and reeled. Add R suffix to device type, (e.g., TL322CDR). schematic (eac h amplifier) Common Bias Circu.

Part

TL322I

Description

Dual Low-Power Operational Amplifier



Feature


ą TL322C, TL322I DUAL LOWĆPOWER OPER ATIONAL AMPLIFIERS ą SLOS086 − D25 67, OCTOBER 1979 − REVISED OCTOBER 19 90 • Wide Range of Supply Voltages S ingle Supply . . . 5 V to 30 V Dual Sup plies . . . ± 2.5 V to ± 15 V • Cla ss AB Output Stage • True Differentia l Input Stage • Low Input Bias Curren t • Internal Frequency Compensation Short-Circuit Protection D OR P PAC.
Manufacture

Texas Instruments

Datasheet
Download TL322I Datasheet




 TL322I
ą
TL322C, TL322I
DUAL LOWĆPOWER OPERATIONAL AMPLIFIERS
ą
SLOS086 − D2567, OCTOBER 1979 − REVISED OCTOBER 1990
Wide Range of Supply Voltages
Single Supply . . . 5 V to 30 V
Dual Supplies . . . ± 2.5 V to ± 15 V
Class AB Output Stage
True Differential Input Stage
Low Input Bias Current
Internal Frequency Compensation
Short-Circuit Protection
D OR P PACKAGE
(TOP VIEW)
1OUT 1
1IN − 2
1IN + 3
VCC− /GND 4
8 VCC +
7 2OUT
6 2IN −
5 2IN +
symbol (each amplifier)
description
The TL322C and the TL322I are dual operational
amplifiers similar in performance to the uA741 but
with several distinct advantages. They are
designed to operate from a single supply over a
range of voltages from 5 V to 30 V. Operation from
split supplies is also possible provided the
difference between the two supplies is 5 V to 30 V.
The common-mode input range includes the
negative supply. Output range is from the negative
supply to VCC −1.5 V. Quiescent supply currents
per amplifier are typically less than one-half those
of the uA741.
The TL322C is characterized for operation from
0°C to 70°C. The TL322I is characterized for
operation from −40°C to 85°C.
IN +
+
IN −
Output
TA
0°C
to
70°c
AVAILABLE OPTIONS
VIO MAX
AT 25°C
PACKAGE
SMALL OUTLINE
(D)
PLASTIC
DIP
(P)
10 mV
TL322CD
TL322CP
0°C
to
70°c
8 mV
TL322ID
TL322IP
D packages are available taped and reeled. Add R suffix to
device type, (e.g., TL322CDR).
schematic (each amplifier)
Common Bias Circuitry
VCC +
IN +
IN −
5 pF
2 k
25
To Other
Amplifier
OUT
60 k
All component values shown are nominal.
2.4 k
VCC −/GND
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
Copyright 1990, Texas Instruments Incorporated
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
1




 TL322I
TL322C, TL322I
ą
DUAL LOWĆPOWER OPERATIONAL AMPLIFIERS
SLOS086 − D2567, OCTOBER 1979 − REVISED OCTOBER 1990
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage VCC + (see Note 1)
Supply voltage VCC (see Note 1)
Supply voltage VCC + (with respect to VCC −)
Differential input voltage (see Note 2)
Input voltage (see Notes 1 and 3)
Continuous total power disspation
Operating free-air temperature range
Storage temperature range
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
TL322C
TL322I
UNIT
18
18
V
− 18
− 18
V
36
36
V
± 36
± 36
V
± 18
± 18
V
See Dissipation Rating Table
0 to 70
−40 to 85
°C
−65 to 150
−65 to 150
°C
260
260
°C
NOTES: 1. These voltage values are with respect to the midpoint between VCC + and VCC −.
2. Differential voltages are at the noninverting input terminal with respect to the inverting input terminal.
3. Neither input must ever be more positive than VCC + or more negative than VCC −.
PACKAGE
D
P
TA 25°C
POWER RATING
680 mW
680 mW
DISSIPATION RATING TABLE
DERATING
FACTOR
5.8 mW/°C
DERATE
ABOVE TA
33°C
8.0 mW/°C
65°C
TA = 70°C
POWER RATING
464 mW
640 mW
TA = 85°C
POWER RATING
377 mW
520 mW
recommended operating conditions
Single supply voltage, VCC
Dual supply voltage, VCC +
Dual supply voltage, VCC
MIN
5
2.5
− 2.5
NOM
MAX
30
15
− 15
UNIT
V
V
V
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001




 TL322I
ą
TL322C, TL322I
DUAL LOWĆPOWER OPERATIONAL AMPLIFIERS
SLOS086 − D2567, OCTOBER 1979 − REVISED OCTOBER 1990
electrical characteristics at specified free-air temperature, VCC± = 15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS†
TL322C
MIN TYP MAX
TL322I
UNIT
MIN TYP MAX
VIO
Input offset voltage
VO = 0,
RS = 50
25°C
Full range
2
10
12
2
8
mV
10
αVIO
IIO
Temperature coefficient of
input offset voltage
Input offset current
VO = 0,
RS = 50
VO = 0
25°C
25°C
Full range
10
30
50
200
10
µV/°C
30
75
nA
250
αIIO
Temperature coefficient of
input offset current
VO = 0
25°C
50
50
pA/°C
IIB
Input bias current
VO = 0
25°C
Full range
−0.2 −0.5
− 0.8
−0.2 −0.5
µA
−1
VICR
Common-mode input
voltage range‡
VCC VCC
VCC VCC
25°C
to
to
to
to
V
13 13.5
13 13.5
VOM
Peak output voltage swing
RL = 10 k
RL = 2 k
25°C
25°C
Full range
± 12 ± 13.5
± 10
± 13
± 10
± 12 ± 12.5
± 10
± 12
V
± 10
AVD
Large-signal differential
voltage amplification
BOM
Maximum-output-
swing bandwidth
VO = ± 10 V,
RL = 2 k
VO(PP) = 20 V,
AVD = 1,
THD 5%,
25°C
Full range
25°C
20
200
15
9
20
200
15
9
V/mV
kHz
RL = 2 k
B1
Unity-gain bandwidth
VO = 50 mV,
RL = 10 k
25°C
1
1
MHz
φm
Phase margin
RL = 2 kΩ,
CL = 200 pF
25°C
60°
60°
ri
Input resistance
f = 20 Hz
25°C
0.3
1
0.3
1
M
ro
Output resistance
f = 20 Hz
25°C
75
75
CMRR Common-mode
rejection ratio
VIC = VICR min,
RS = 50
25°C
70
90
70
90
dB
kSVS
IOS
Supply voltage sensitivity
(VIO/ VCC)
Short-circuit output current§
VCC = ± 2.5 V to
± 15 V,
RS = 50
VO = 0
25°C
25°C
30 150
30 150 µV/V
± 10
± 30 ± 45
± 10
± 30 ± 45 mA
ICC
Total supply current
VO = 0,
No load
25°C
1.4
4
1.4
4 mA
All characteristics are under open-loop conditions unless otherwise noted. Full range for TA is 0°C to 70°C for TL322C and − 40°C to 85°C for
TL322I.
The VICR limits are directly linked volt-for-volt to supply voltage; the positive limit is 2 V less than VCC +.
§ Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
3



Recommended third-party TL322I Datasheet






@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)